High Quality Flow Meter Electromagnetic Flowmeter for Sewage

Product Details
Customization: Available
Warranty: One Year
Type: Electromagnetic Flowmeter
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000
  • High Quality Flow Meter Electromagnetic Flowmeter for Sewage
  • High Quality Flow Meter Electromagnetic Flowmeter for Sewage
  • High Quality Flow Meter Electromagnetic Flowmeter for Sewage
  • High Quality Flow Meter Electromagnetic Flowmeter for Sewage
  • High Quality Flow Meter Electromagnetic Flowmeter for Sewage
  • High Quality Flow Meter Electromagnetic Flowmeter for Sewage
Find Similar Products
  • Overview
  • Base weight valve
  • Detailed Photos
  • Product Parameters
  • RC81 Consistency Transmitter
  • Blade Consistency Transmitter
  • Flowmeter
  • Company Profile
Overview

Basic Info.

Model NO.
LZ-FMEF0607
Sheet Former Type
Fourdrinier Wire
Paper Thickness
Normal Specification Paper
Automation
Automatic
Certification
CE
Customized
Customized
Condition
New
Sensor
Tube / Flange
Main Application
Water, Wastewater, Corrosive Liquid/Gas, Sludge /
Electrode Material
SUS316L/Hastelloy/Ta/Ti/Platinum
Package
Fully Wooden Cartons with Foaming Inside.
Seaport
Qingdao Seaport
Transport Package
Standard Sea Worth Package
Specification
stainless steel/carbon steel
Trademark
LEI ZHAN
Origin
China
HS Code
902610000
Production Capacity
2500 Set/Year

Product Description

Base weight valve

Quantitative control is the key link of papermaking, the quality of material discharge directly affects the quality and pass rate of paper forming paper. The control accuracy of electric material door is one thousandth, can fine- tune the material door, so as to accurately control the quantitative. Electric door repeat accuracy is high, in the paper machine to change different varieties, easy operators will be the door one step to adjust in place, reduce loss of paper / reduce costs. System composition: electric door has electric adjustment quantitative valve and valve controller composition.
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
In a paper mill, it is very important to detect the flow of pulp entering the head box. This flow parameter directly participates in the control of the paper quantification. Due to changes in head box pressure and liquid level, the amount of pulp jetted onto the mesh through the lip plate will fluctuate. Therefore, controlling the stability of the head box pulp flow is vital to the control of the paper basis weight, and it will also directly affect the paper's quality. The final quality.      
Through the measurement of the thickness and moisture of the final finished paper, the flow of pulp is controlled, which is called the "quantitative control system", and is usually considered to be the most important part of the paper machine "QCS" system.

The measurement of pulp flow usually uses electromagnetic control valve system.

 

Detailed Photos

 
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
 

Product Parameters


Because of its structural characteristics, it is suitable for the control of related process parameters in the suspension medium containing fibers or small solid particles in papermaking, chemical, metallurgical and other industrial enterprises. It is especially suitable for the pulp in the pulping and papermaking production process. , White water, black liquor, white liquor and other suspended particle fluids and the automatic adjustment of thick and turbid slurry fluid media.
System composition Electric door has electric adjustment quantitative valve and valve controller composition.
Precision Controlled at 1-2 ‰ during fine-tuning
Maximum output torque 4000N·m
Working power supply 220V AC 1Phase,50/60 Hz, ±10%
Ball valve size DN150
 

RC81 Consistency Transmitter

 
RC81 Consistency Transmitter application and environmental conditions
RC81 concentration sensor has high sensitivity, good anti-vibration performance, and is almost insensitive to slurry flow rate. It can be applied to all aspects of pulp concentration detection and control in papermaking and pulping processes of papermaking enterprises.
Ambient temperature 0~60 0C
Medium temperature 0~90 0C
Environmental humidity ≤85%RH
External magnetic field ≤400A/m (5 Oersted)
Dilution water pressure 0.2~0.4MPa
Vibration amplitude ≤0.05mm frequency ≤25Hz
Slurry flow rate 0.5~5m/s
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
                                                                       Technical Parameters of RC81 Consistency Transmitter
Working range: better than ±0.005%
1~16% concentration (according to measuring components) 1~16% concentration (according to measuring components)
Measurement accuracy: close to sensitivity under stable conditions
Damping time: 1~100S
Maximum working pressure: 1MPa, 80°C
Shell: cast aluminum
Motor: 3-phase 380VAC, 370W, IP54
Analog signal output: 4~20mA, load 0~750Ω
 

Blade Consistency Transmitter

 
High Quality Flow Meter Electromagnetic Flowmeter for Sewage

The BC20 concentration sensor is an embedded system intelligent sensor, the signal is industry standard 4 ~ 20mA and RS-422 output, matching the BC20 converter, BC20 converter built-in Liquid Crystal Display and control unit, the sensor can be fully accurate calibration and operation, can be multi-point and single point calibration, calibration curve LCD.
In the measurement of pulp consistency, the shearing force is the most mature.
The BC20 concentration sensor actively measures the force signal produced by the shearing pulp suspension, which is converted into an electrical signal by a microprocessor. This method is insensitive to the normal changes of fiber composition, degree of freedom, filler, flow rate and pressure in the pulp suspension. The utility model overcomes the defects that the zero point of the fixed knife type sensor is easy to drift and is greatly influenced by the current velocity, and has a high performance-price ratio. 

 

Technical parameter  
Measuring principle, using the pulp shearing force to measure.  
Working range:1.5 ~ 8% concentration  
The sensitivity : better than ± 0.0075% (under laboratory control)  
Damping Time :1 ~ 100s  
Flow rate: 0.5 ~ 5 m/s  
The repeatability  :better than ± 0.03% of full range (under stable working condition)  
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
 

Flowmeter

 
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
Products Description :

Flow meters are widely used in the measurement and control of superheated steam,saturated steam,compressed air and general gases (oxygen,nitrogen,hydrogen,natural gas,gas,ete.). water and liquids(such as water,gasoline,alcohol,benzene,ete.)in petroleum,chemical,metallurgy,heat,textile,paper and other industries.

Working Prnciple

If a non-streamline vortex generator (blocking fluid)is set in the ftuid,then two regular vortexes will begenerated alternately from both sides of the vortex generator.
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
High Quality Flow Meter Electromagnetic Flowmeter for Sewage
 

Company Profile

High Quality Flow Meter Electromagnetic Flowmeter for Sewage

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier